Manually shutting down unidirectional links, Network requirements, Configuration procedure – H3C Technologies H3C S12500 Series Switches User Manual

Page 62

Advertising
background image

51

Manually shutting down unidirectional links

Network requirements

As shown in

Figure 10

,

Two switches, Device A and Device B, are connected with two fiber pairs.

Make configuration so that DLDP, upon detecting a unidirectional link, reminds the network
administrator to manually shut down the faulty port.

Figure 10 Network diagram

Configuration procedure

1.

Configure Device A:
# Enable DLDP globally.

<DeviceA> system-view

[DeviceA] dldp enable

# Configure Gigabitethernet 2/0/1 to operate in full duplex mode, configure the port rate as
1000 Mbps, and enable DLDP on the port.

[DeviceA] interface gigabitethernet 2/0/1

[DeviceA-Gigabitethernet2/0/1] duplex full

[DeviceA-Gigabitethernet2/0/1] speed 1000

[DeviceA-Gigabitethernet2/0/1] dldp enable

[DeviceA-Gigabitethernet2/0/1] quit

# Configure Gigabitethernet 2/0/2 to operate in full duplex mode, configure the port rate as

1000 Mbps, and enable DLDP on the port.

[DeviceA] interface gigabitethernet 2/0/2

[DeviceA-Gigabitethernet2/0/2] duplex full

[DeviceA-Gigabitethernet2/0/2] speed 1000