:RESOlution:CURRent:DC 1


5. :RESOlution:CURRent:AC
Syntax

:RESOlution:CURRent:AC?
:RESOlution:CURRent:AC {0|1|2|MIN|MAX|DEF}

Function

Set the reading resolution of AC current measurement.
The query returns 0, 1 or 2.

Explanation

 The AC current measurement function must be enabled before

using this command.

 For the reading resolution of each parameter, please refer to

Explanation” in :RESOlution:VOLTage:AC.

Example

Set the reading resolution of AC current measurement to 5 ½
digits:
:RESOlution:CURRent:AC 2


6. :RESOlution:RESistance
Syntax

:RESOlution:RESistance?
:RESOlution:RESistance {0|1|2|MIN|MAX|DEF}

Function

Set the reading resolution of 2-wire resistance measurement.
The query returns 0, 1 or 2.

Explanation

 The 2-wire resistance measurement function must be enabled

before using this command.

 For the reading resolution of each parameter, please refer to

the Explanation” in :RESOlution:VOLTage:DC.

Example

Set the reading resolution of 2-wire resistance measurement to
5 ½ digits:
:RESOlution:RESistance 1


7. :RESOlution:FRESistance
Syntax

:RESOlution:FRESistance?
:RESOlution:FRESistance {0|1|2|MIN|MAX|DEF}

Function

Set the reading resolution of 4-wire resistance measurement.
The query returns 0, 1 or 2.

Explanation

 The 4-wire resistance measurement function must be enabled

before using this command.

 For the reading resolution of each parameter, please refer to

the Explanation” in :RESOlution:VOLTage:DC.