<slope> can be POSitive or NEGative.

[SENSe:]PERiod:APERture? [{MIN|MAX}]
[SENSe:]PERiod:APERture
{<second>|MIN|MAX|DEF}

Query and set the aperture time of period
measurement.
Note: DM3000 only receives the command but
does not respond to it.

[SENSe:]PERiod:NULL[:STATe]?
[SENSe:]PERiod:NULL[:STATe] {ON|OFF}

Query and set the state of the NULL function of
period measurement.

[SENSe:]PERiod:NULL:VALue? [{MIN|MAX}]
[SENSe:]PERiod:VALue {<value>|MIN|MAX}

Query and set the NULL value of period
measurement.

[SENSe:]PERiod:VOLTage:RANGe:AUTO?
[SENSe:]PERiod:VOLTage:RANGe:AUTO
<mode>

Query and set the state of the voltage auto range
function of period measurement.

[SENSe:]PERiod:VOLTage:RANGe[:UPPer]?
[{MIN|MAX}]
[SENSe:]PERiod:VOLTage:RANGe[:UPPer]
{<voltage_range>|MIN|MAX|DEF}

Query and set the voltage range of period
measurement.

[SENSe:]RESistance:APERture? [MIN|MAX]
[SENSe:]RESistance:APERture
{<second>|MIN|MAX|DEF}

Query and set the aperture time of 2-wire resistance
measurement.
Note: DM3000 only receives the command but
does not respond to it.

[SENSe:]RESistance:NPLC? [{MIN|MAX}]
[SENSe:]RESistance:NPLC
{<PLCs>|MIN|MAX|DEF}

Query and set the integral time of 2-wire resistance
measurement. The input value and return value are
both multiples of PLC.
Note: DM3000 only receives the command but
does not support the NPLC value setting function.

[SENSe:]RESistance:NULL[:STATe]?
[SENSe:]RESistance:NULL[:STATe]
{ON|OFF}

Query and set the state of the NULL function of
2-wire resistance measurement.

[SENSe:]RESistance:NULL:VALue?
[{MIN|MAX}]
[SENSe:]RESistance:NULL:VALue
{<value>|MIN|MAX}

Query and set the NULL value of 2-wire resistance
measurement.

[SENSe:]RESistance:RANGe:AUTO?
[SENSe:]RESistance:RANGe:AUTO <mode>

Query and set the state of the auto range function
of 2-wire resistance measurement.

[SENSe:]RESistance:RANGe[:UPPer]?
[{MIN|MAX}]
[SENSe:]RESistance:RANGe[:UPPer]

Query and set the range of 2-wire resistance
measurement.