Chapter 5 Instruction Specifications

5-73

Program example

X00000

X00001 DIF1

R7F2

R7F0

Y00100

SHR (DR0000,1)

X00000 . . . . .

X00001 . . . . .

. . . . .

LD

X00000

OUT R7F2
LD

X00001

AND DIF1
[
SHR

(DR0000,1)

]
LD

R7F0

OUT Y00100

Defective unit input
To SD

Conveyor movement

Defective unit output
Carry

Y00001

Program description

• There exists a conveyor that has 16 stands and is moving to the right.
• Each time the conveyor moves one stand to the right, a pulse input enters X1.
• There is a sensor on the left end of the conveyor, and when a defective unit is placed on the conveyor, X00000 turns on.

X00000 (sensor input) and X00001 (conveyor movement) signals are as follows:

X00000

X00001

• As the conveyor moves to the right, the data is also shifted one bit at a time, and when data exits to the carry (on the right

end of the conveyor), the (Y00100) solenoid valve turns on and rejects the defective unit.

b16

(Y00100)

b0

X00001

0

1

0

0

1

0

0

0

0

1

0

b16

b0

SD (R7F2)

X00000

C (R7F0)

Y00000

Sensor (X00000)

Solenoid valve

Conveyor movement

Shifts one bit at a time

SH