Hitachi NJI-350B User Manual

Page 169

Advertising
background image

Chapter 5 Instruction specifications

5-119

Sample program

Description

TRNS 0 parameter and sent data are configured at 1

st

scan by R7E3 contact.

When the switch is ON, execution bit R0 is ON, and data is sent out from CPU port.

TR

N

S

0

(

d, s, t)

R7E3

WM103 = 0
WM104 = H000A
WM105 = H0000
WM106 = 16
WM107 = H000A
WM108 = H0100
WM109 = 256
WM10A = 0
WM10B = H8002
WM10C = H800D
WM10D = 6
WM10E = 0
WR10 = H0200
FUN 5 (WR10)

R7E3 : 1

st

scan ON

Timeout = 0

Reserve area for data sending :
16 words from WR0

Reserve area for data receiving :
256 words from WR100

Data receiving definition
Start code : H02, End code : H0D

Communication speed : 19.2k bps
Format : 7 bits, even, 2 stop

Port 2 configured as general purpose port.

R7E3

WR100 = 9
WR101 = H0231
WR102 = H3830
WR103 = H3031
WR104 = H3338
WR105 = H0D00

Sent data : 9 bytes
Inverter (SJ300/L300P) command
FWD RUN for station No.18
02 31 38 30 30 31 33 38 0D
(STX 18 00 1 38 CR) [38=BCC]

Switch

R0

TRNS 0 (WY10, WM100, R0)

When the switch is ON, execution bit R0 is ON, and
data is sent out from CPU port.

R5 enables data receiving from the other device.

WR0

WR100

DIF0

S

R5

S