Chapter 12 Error Code List and Special Internal Outputs

12-11

No.

Name

Stored data

Description

Setting

condition

Resetting

condition

WRF057

Detailed information
of counter setting
errors

a: Error in pulse frequency total
b: Pulse 4 frequency

c: Pulse 3 frequency

d: Pulse 2 frequency

e: Pulse 1 frequency

f: Counter 4 preset

g: Counter 3 preset

h: Counter 2 preset

i: Counter 1 preset

0=Normal, 1=Error

Set by the
system

Cleared by
the system

WRF058

PI/O function
individual setting
request 1 *

a: Output number (during pulse setting)

Off-preset (during counter setting)

b: On-preset (during counter setting)

Frequency (during pulse setting), frequency, on-duty (during
PWM setting)

0=No changes, 1=Change request

Set by user

Cleared by
the system

WRF059

PI/O function
individual setting
request 2 *

a: Output number (during pulse setting)

Off-preset (during counter setting)

b: On-preset (during counter setting)

Frequency (during pulse setting), frequency, on-duty (during
PWM setting)

0=No changes, 1=Change request

Set by user

Cleared by
the system

WRF05A

PI/O function
individual setting
request 3 *

a: Output number (during pulse setting)

Off-preset (during counter setting)

b: On-preset (during counter setting)

Frequency (during pulse setting), frequency, on-duty (during
PWM setting)

0=No changes, 1=Change request

Set by user

Cleared by
the system

WRF05B

PI/O function
individual setting
request 4 *

a: Output number (during pulse setting)

Off-preset (during counter setting)

b: On-preset (during counter setting)

Frequency (during pulse setting), frequency, on-duty (during
PWM setting)

0=No changes, 1=Change request

Set by user

Cleared by
the system

WRF05D

to F06A

Undefined

Do not use.

15 14

8

7

6

5

4

3

2

1

0

a

Not used

b

c

d

e

f

g

h

i

15

2

1

0

Not used

a

b

15

2

1

0

Not used

a

b

15

2

1

0

Not used

a

b

15

2

1

0

Not used

a

b