Chapter 5 Instruction Specifications

5-131

Item number

FUN instructions-7

Name

High-speed Counter Up-Count/Down-count Control (Single
phase counter only)

Ladder format

Condition code

Processing time (

µs)

Remark

R7F4

R7F3

R7F2

R7F1

R7F0

Average Maximum

FUN 142 (s)

DER

ERR

SD

V

C

z

z

z

z

Instruction format

Number of steps

156

Condition

Steps

FUN 142 (s)

3

Bit

Word

Double word

Usable I/O

X

Y

R,

M

TD, SS,

CU, CT

WX WY

WR,

WM TC DX DY

DR,

DM

C

onstant

Other

s

Argument (Counter
number, Up/Down
instruction)

{

Function

Counter number:

H01 to H04

Up/down instruction: H00 – Up-count,

H01 – Down-count

• This controls the up-count/down-count of the specified counter.
• Up-count and down-count control can be performed during the count operation.

Notes

• If a value other than H01 to H04 is specified for the counter number and the up/down instruction is set to a value other than

H00 or H01, DER will be set to “1”and no processing will be performed.

• If the specified counter number is set to a function other than single-phase counter, DER will be set to “1” and no processing

will be performed.

• Since Counter 4 is invalid when a 10-point CPU is used, if Counter 4 is specified, DER will be set to “1” and no processing

will be performed.

• If the specified counter number is unable to make an output (PI/O function setting result by R7F5), DER will be set to “1”

and no processing will be performed.

• This instruction is only used to control the up-count and down-count. Other counter settings will not be changed and it will

not affect the count operation.

• The control contents of this instruction will be reflected in bits 11 to 8 of the special internal output WRF07E of the

corresponding counter number.

Program example

R2

LD

R2

AND DIF2
[
WR2 = H101
FUN 142 ( WR2 )
]

DIF2

WR2 = H0101
FUN 142 (WR2)

Program description

• Switches the counter operation of the counter No. 1 to down count.

The count edges (leading/trailing) will follow the specification of the special internal output (WRF07E).