Chapter 8 High-speed counter, PWM / Pulse train output and Analogue I/O

8-11

(2)

Phase counting mode 1

In this mode the counter counts at the rising edge of input 1A. At this point, if input 1B is 0 (Low) it counts up, and if
input 1B is 1 (High) it counts down.

Figure 8.15 Counting operation of phase counting mode 1

Input 1A

Input 1B

Operation

1 (High)

↑ (Rising edge)

Do not count

0 (Low)

↓ (Falling edge)

↓ (Falling edge)

1 (High)

↑ (Rising edge)

0 (Low)

Up count

0 (Low)

↑ (Rising edge)

Do not count

1 (High)

↓ (Falling edge)

↓ (Falling edge)

0 (Low)

↑ (Rising edge)

1 (High)

Down count

(3)

Phase counting mode 2

In this mode, if input 1B is 0 (Low) at the rising edge of input 1A the counter counts up, and if input 1A is 0 (Low) at the
rising edge of input 1B, the counter counts down.

Figure 8.16 Counting operation of phase counting mode 2

Input 1A

Input 1B

Operation

1 (High)

↑ (Rising edge)

Do not count

0 (Low)

↓ (Falling edge)

↓ (Falling edge)

1 (High)

↑ (Rising edge)

0 (Low)

Up count

0 (Low)

↑ (Rising edge)

Down count

1 (High)

↓ (Falling edge)

Do not count

↓ (Falling edge)

0 (Low)

↑ (Rising edge)

1 (High)

Coincidence
output

On preset

Off preset

Count value

Input 1B

Input 1A

Coincidence
output

On preset

Off preset

Count
value

Input 1B

Input 1A