Hitachi NJI-350B User Manual

Page 221

Advertising
background image

Chapter 8 High-speed counter, PWM / Pulse train output and Analogue I/O

8-12

(4)

Phase counting mode 3

In this mode the counter counts at the rising and falling edge of input 1B. It counts up when input 1A is more ahead of
input 1B, and down when input 1A is lagging behind input 1B.

Figure 8.17 Counting operation of phase counting mode 3

Input 1A

Input 1B

Operation

1 (High)

↑ (Rising edge)

Up count

0 (Low)

↓ (Falling edge)

↓ (Falling edge)

1 (High)

Do not count

↑ (Rising edge)

0 (Low)

0 (Low)

↑ (Rising edge)

Down count

1 (High)

↓ (Falling edge)

↓ (Falling edge)

0 (Low)

Do not count

↑ (Rising edge)

1 (High)

(5)

Clear input operation (common to all the phase counting modes)

The count value is cleared at the rising edge of input 1Z. As an example, the clear operation of phase counting mode 4 is
shown in Figure 8.18. (The clear operation works identically for all four phase counting modes.)

Figure 8.18 Count value clear operation (phase counting mode 4)

Coincidence
output

On preset

Off preset

Count
value

Input 1B

Input 1A

Coincidence
output

On preset

Off preset

Count
value

Input 1Z

Input 1B

Input 1A