Chapter 11 Communication Specifications

11-1

Chapter 11 Communication Specifications

11.1 Port function

Port function of MICRO-EH is shown in Table 11.1.

Table 11.1 Communication port specification

RS-232C

RS-422/485

Dedicated port

Dedicated port

Transmission procedure 1

Transmission

procedure 2

Port type

Transmission

procedure 1

Trans.
proce-
dure 2

Without St. No.

(1:1)

With

St. No.

(1:N)

Without

St. No.

(1:1)

With

St. No.

(1:N)

Connected devices

Programming device,

PC, modem, HMI

PC,
etc.

PC,
etc.

Programming

device, PC, HMI

PC, etc.

PC, etc.

PC,
etc.

PC,
etc.

Port 1

All modules

9

9

9*

-

-

-

-

-

Port 2

23,28 pts. module

-

-

-

9

9

9

9

9*

* Supported by software version 1.30 (WRF051=H0130) or newer.

11.2 Port 1

Specification of port 1 is shown below.

Table 11.1 Port 1 specification

Item

Specification

Communication

Dedicated (programming) port

Modem mode

General purpose port

speed*

4800, 9600, 19.2k, 38.4k bps

2400, 4800, 9600, 19.2 k, 38.4k,
57.6 k bps

300, 600, 1200, 2400, 4800,
9600, 19.2k, 38.4k, 57.6k bps

Communication system Half duplex
Synchronization

Asynchronous

Startup system

One-sided startup using the host side command

Transmission system

Serial transmission (bit serial transmission)

Transmission code

ASCII

Configured by user

Transmission code
configuration

ASCII: 7-bit data, 1 start, 1 stop, even parity

2

0

2

1

2

6

P

Start bit (1 bit)

Parity bit (1 bit)

Stop bit (1 bit)

Data (7 bits) (even parity)

Configured by user

Data sending sequence Sent out from the lowest bit
Error control

Vertical parity check, checksum, overrun check, framing check

Transmission unit

Message unit (variable length)

Max. message length

1,024 bytes (including control characters)

Control procedure

H-series dedicated procedure (hi-protocol)
Standard protocol (transmission control procedure 1),
Simplified protocol (transmission control procedure 2)

Configured by user

Interface

RS-232C (maximum cable length: 15 m)

Connector

8P modular connector (RJ45)

* : Handy programmers are not available with MICRO-EH.
* : GPCL01H is not available with 10 points type as communication speed is fixed as 4,800 bps.
* : If host sends NAK command, the next message must be sent after 10 ms interval.