5 word special internal output area – Hitachi NJI-350B User Manual

Page 272

Advertising
background image

Chapter 12 Error Code List and Special Internal Outputs

12-9

12.5 Word Special Internal Output Area

The following lists the definitions of the word special internal output area (WRF000 to WRF1FF).

No.

Name

Storage data

Description

Setting

condition

Resetting

condition

WRF000

Self-diagnosis error
code

Error code
(Hexadecimal)

WRF001

Syntax/Assembler
error details

Syntax/Assembler error
code (Hexadecimal)

Error code for user program
Syntax/Assembler error is stored

WRF002

Further information
of I/O configuration
error

Mismatched slot number

a: Unit number (0 to 5)
b: Slot number (0 to F)

Set by the
system

Cleared by
user

WRF003

-F00A

Undefined

Do not use.

WRF00B

Year

4 digit year [yyyy]

WRF00C

Month / date

[mm dd]

WRF00D

Day of the week

Sunday: 0000 to Saturday: 0006

WRF00E

Hour / minute

[hh mm] (24-hour system)

WRF00F

Calendar and clock
present value
(4 digit BCD)

Seconds

[00 ss]

Set by the
system

Always
displayed

WRF010

Scan time
(maximum value)

Max. scan time

× 10 ms

WRF011

Scan time
(present value)

Current scan time

× 10 ms

WRF012

Scan time
(minimum value)

Min. scan time

× 10 ms.

(HFFFF at 1

st

scan)

Cleared by
the system (in
the RUN
starts)

WRF013

CPU status

a: CPU type (0011),

b: Battery error (1=error, 0=no error),

c: Not used,

d-g: Not used (Fixed to 0),

h: Halt (1=executing, 0=not executing),
i: CPU operation (1=RUN, 0=STOP)

Always
displayed

WRF014

Word internal output
capacity

Number of words for word internal output (WR) = H1000

Always
displayed

WRF015

Operation error code Operation error code

WRF016

Division remainder
register (low word)

Remainder data when division instruction executed

WRF017

Division remainder
register (high word)

Remainder data when division instruction executed
(Used only at double word operation)

Set by the
system

Cleared by
user

WRF018-

F019

Undefined

Do not use.

WRF01A

Setting of
Com. port 1

a:

Transmission control procedures (0- Standard, 1-Simplified)

b-c: Not used
d:

Baud rate during modem connection

= 00000: 4800 bps, = 00001: 9600 bps, = 00010: 19.2 kbps
= 00011: 38.4 kbps, = 00100: 57.6 kbps, = 00101: 2400 bps
= 4800 bps for other than the above

Set by user

Cleared by
user

WRF01B

Year

4 digit year [yyyy]

WRF01C

Month / date

[mm dd]

WRF01D

Day of the week

Sunday: 0000 to Saturday: 0006

WRF01E

Hour / minute

[hh mm] (24-hour system)

WRF01F

Reading or writing
register for calendar
and clock
(4 digit BCD)
Use with R7F8 or
R7F9

Seconds

[00 ss]

Set by system
or user

Cleared by
user

WRF020

to F03B

Undefined

Do not use.

15 12

11 8

7 4

3 0

0

a

b

0

15 14 13 12 11

8

7

6

5

4

3

2

1

0

Unused

a

b

c

d

e

f

g

h

i

15 14 13 12

8

7

0

a

b

c

d

Unused

Advertising