8 chassis brake resistors (accessory), 1 electrical data chassis br, 2 dimensions chassis br – NORD Drivesystems BU0700 User Manual

Page 15: B1 l1 b2 l2 t

Advertising
background image

2 Assembly and installation

BU 0700 GB-1411

Subject to technical alterations

15

B1

L1

B2

L2

T

2.8 Chassis brake resistors (accessory)

During dynamic braking (frequency reduction) of a three phase motor, electrical energy is released and returned to the
frequency inverter. To prevent a safety shut-down of the frequency inverter, the integrated brake
chopper can be activated by the connection of an external brake resistor.

The returned energy is converted into heat, so avoiding a possible overvoltage.

All chassis resistors are UL certified and are not subject to
restrictions in the North American market.

Connection is with screw connectors that are designated +B, -
B (1.5-22kW) or BR, +ZW (30-160kW), and the safety leads.

For overload protection, a thermal switch is located close to
a brake resistor. The switch is freely available via the
screw connectors (2 x 4mm

2

). The switching capacity is

limited to 250VAC/10A, 125VAC/15A and 30VDC/5A.

2.8.1 Electrical data Chassis BR

Inverter type

NORDAC SK 700E

Resistor type

Resistance

Continuous

output (approx.)

*) Pulse output

(approx.)

Connection

terminals

1.5 ... 2.2 kW

SK BR2- 200/300-C

200

300 W

3 kW

10 mm

2

3.0 ... 4.0 kW

SK BR2- 100/400-C

100

400 W

6 kW

10 mm

2

5.5 ... 7.5 kW

SK BR2- 60/600-C

60

600 W

9 kW

10 mm

2

11 ... 15 kW

SK BR2- 30/1500-C

30

1500 W

20 kW

10 mm

2

18.5 ... 22 kW

SK BR2- 22/2200-C

22

2200 W

28 kW

10 mm

2

30 ... 37 kW

SK BR2- 12/4000-C

12

4000 W

52 kW

10 mm

2

45 ... 55 kW

SK BR2- 8/6000-C

8

6000 W

78 kW

10 mm

2

75 ... 90 kW

SK BR2- 6/7500-C

6

7500 W

104 kW

25 mm

2

110 ... 160 kW

SK BR2- 3/7500-C

3

7500 W

110 kW

25 mm

2

*) permissible, depending on application, max. 5% ED

2.8.2 Dimensions Chassis BR

Resistor type

Length

L1

Width

B1

Depth

T

Fixing dimensions

Length L2

Width B2

SK BR2- 200/300-C

100

170

240

90

150

4.3

SK BR2- 100/400-C

SK BR2- 60/600-C

350

92

120

325

78

6.5

SK BR2- 30/1500-C

560

185

120

530

150

6.5

SK BR2- 22/2200-C

460

270

120

430

240

6.5

SK BR2- 12/4000-C

560

270

240

530

240

6.5

SK BR2- 8/6000-C

470

600

300

440

2 x 220

6.5

SK BR2- 6/7500-C

570

600

300

540

2 x 220

6.5

SK BR2- 3/7500-C

All dimensions in mm

Basic diagram,

design varies according to output

Advertising