3.3 Special extension units

(EXtension Unit, Option)

Special extension units are very similar to the
customer units; they are however designed for
other functions and can only be placed in the lower
slots. After insertion, they are automatically
identified by the frequency inverter.

Cable connection is via direct plug-in clip
connectors
with spring terminals. This makes the
connection of devices very easy and convenient.

Special extension unit

SK XU1-...

Description

Data

Encoder

SK XU1-ENC

For highly accurate speed control from standstill to

double the rated speed

1 x digital input

1 x encoder input, RS 422

up to 250kHz

PosiCon

SK XU1-POS

Programmable positions are reached and

maintained by means of path calculations. The

actual value acquisition is with an incremental or

absolute value encoder

Up to 252 positions

6 x digital inputs

2 x multifunction relays

1 x SSI interface, RS 422

1 x encoder input, RS 422

up to 250kHz

NOTE

,

for 5V / 15V power supplies

The customer units and special extension units currently have various power supplies (5V / 15V) that can
be used externally. The maximum permissible external load current is 300mA. This can be taken from
one or more power supplies. The total current must however not exceed 300mA.
All control voltages are based on a common reference potential!

Potentials AGND /0V und GND /0V are internally linked in the device.