5.1.3 Motor data

BU 0700 GB-1411

Subject to technical alterations

75

Parameter

Setting value / Description / Note

Available with option

P326

Ratio encoder

ENC POS

0.01...200.0

[ 1.00 ]

If the incremental encoder is not mounted directly onto the motor shaft, then the respectively correct
transformation ratio of motor speed to encoder speed must be set.

speed

Encoder

speed

Motor

P326

Only when P325 = 1, 2, 3 or 4, therefore not in Servo mode (motor speed control)

P327

Speed slip error

ENC POS

0...3000 min

-1

[ 0 ]

The limit value for a permitted maximum slip error can be set. If this value is reached, the FI switches
off and indicates error E013.1.

0 = OFF

Only when P325 = 0, therefore in Servo mode (motor speed control)

P330

Digital input function 13

ENC

0...3

[ 0 ]

0 = Off: No function, input is switched off.

1 = Servo Mode On / Off: Activation and deactivation of the Servo mode using an external signal

(High level = active). For this P300 = 1 (Servo mode = On).

2 = Sensor monitoring: A connected incremental encoder receives a fault signal and indicates fault

functions like e.g. break in the supply line or light source failure.
The FI shows Error 13, Encoder error, if there is an error.

3 = PTC resistor input: Analog evaluation of the present signal switching threshold, approx. 2.5 Volt.