5.1.5 Control terminals

BU 0700 GB-1411

Subject to technical alterations

87

Parameter

Setting value / Description / Note

Available with option

P480

.. - 01

...

.. - 12

Function Bus I/O In Bits

always visible

0 ... 62
[ 12 ]

The Bus I/O In Bits are perceived as digital inputs. They can be set to the same functions (P420...425).

[01] = Bus I/O In Bit 1
[02] = Bus I/O In Bit 2
[03] = Bus I/O In Bit 3
[04] = Bus I/O In Bit 4
[05] = Bus I/O Initiator 1
[06] = Bus I/O Initiator 2

[07] = Bus I/O Initiator 3
[08] = Bus I/O Initiator 4

The possible functions for the Bus In Bits can be found in the table of functions for the digital inputs
P420...425.
Further details can be found in the manuals for each Bus system.

P481

.. - 01

...

.. - 10

Function Bus I/O Out Bits

always visible

0 ... 38
[ 10 ]

The Bus I/O Out Bits are perceived as multi-function relay outputs. They can be set to the same
functions (P434...443).

[01] =

Bus I/O Out Bit 1

[02] =

Bus I/O Out Bit 2

[03] =

Bus I/O Out Bit 3

[04] =

Bus I/O Out Bit 4

[05] =

Bus I/O Actuator 1

[06] =

Bus I/O Actuator 2

[07] =

Flag 1

[08] =

Flag 2

The possible functions for the Bus Out Bits can be found in the table of functions for the relay P434.
Further details can be found in the manuals for each Bus system.

P482

.. - 01

...

.. - 08

Normalisation Bus I/O Out Bits

always visible

-

400 … 400 %

[ 100 ]

Adjustment of the limit values of the relay functions/Bus Out Bits. For a negative value, the output
function will be output negative.
When the limit value is reached and the setting values are positive, the relay contact closes, with
negative setting values the relay contact opens.

P483

.. - 01

...

.. - 08

Hysteresis Bus I/O Out Bits

always visible

1 … 100 %
[ 10 ]

Difference between switch-on and switch-off point to prevent oscillation of the output signal.