1. Allgemeines

BU 0700 GB-1411

Subject to technical alterations

7

CAUTION

Children and the general public must be kept away from the equipment!

The equipment may only be used for the purpose intended by the manufacturer. Unpermitted

modifications and the use of spare parts and additional equipment that has not be bought from or
recommended by the equipment manufacturer can lead to fire, electric shock and injury.

Keep these operating instructions in an accessible location and ensure that every operator uses it!

Warning:

This product is covered under marketing classification IEC 61800-3. In a domestic environment, this product can
cause high frequency interference, which may require the user to take appropriate measures.

An appropriate measure would be the inclusion of a recommended line filter.

1.5 Certifications

1.5.1 European EMC guideline

If the NORDAC SK 700E is installed according to the recommendations in this instruction manual, it
meets all EMC directive requirements, as per the EMC product standard for motor-operated systems
EN 61800-3.

(See also Chapter 8.3 Electromagnetic compatibility [EMC].)

1.5.2 UL and cUL certification

(Used in North America)

“Suitable for use on a circuit capable of delivering not more than 5000 rms symmetrical
amperes, 380…480 Volts (three phase)” and “when protected by 600V J class fuses”
(Frequency inverter size 1 … 4), resp. „when protected by 600V R class fuses or faster”
(Frequency in

verter size 5 … 7) as described in Chapter 7.4."

Suitable for use on a circuit capable of delivering not more than 5000A (symmetrical),
380...460 Volts (three phase) and when protected by "600V J class fuses" (Size 1 ...4
frequency inverters) or a "600V R class fuse or faster" (Size 5 ... 7 frequency inverters) as described in Chap. 7.4.

NORDAC SK 700E frequency inverters have motor overload protection.
Further technical details can be found in Section 7.4.

Not incorporated Overspeed Protection.

Relays on extension units and customer interface units may only be used at 230V ac maximum, same phase only.

Maximum Surrounding Air Temperature 40°C.

Torque Value for field wiring terminals:
o Models SK700E-151-340-A up to SK700E-751-340-

A (mains circuit, motor, braking resistor): 4.4 … 5.3 lb-in (0.5 … 0.6 Nm)

o Models SK700E-112-340-A up to SK700E-152-340-A (mains circui

t, motor, braking resistor): 11 … 13.27 lb-in (1.2 … 1.5 Nm)

o Models SK700E-182-340-A up to SK700E-222-340-

A (mains circuit, motor, braking resistor): 21.2 … 35.4 lb-in (2.4 … 4.0 Nm)

o Models SK700E-302-340-A up to SK700E-372-340-A

Mains circuit: 53.1 … 70.8 lb-in (6 … 8Nm)
motor and braking resistor: 28.32 … 32.74 lb-in (3.2 … 3.7 Nm)

o Models SK700E-452-340-A up to SK700E-552-340-A

Mains circuit and motor: 53.1 … 70.8 lb-in (6 … 8 Nm)
braking resistor: 28.32 … 32.74 lb-in (3.2 … 3.7Nm)

o Models SK700E-752-340-A up to SK700E-902-340-A

Mains circuit and motor: 132.7 … 177 lb-in (15 … 20Nm)
braking resistor: 53.1 … 70.8 lb-in (6 … 8Nm)