3.2 Customer unit

BU 0700 GB-1411

Subject to technical alterations

49

3.2.5 BUS customer units

(SK CU1-USS, SK CU1-CAN/-RJ, SK CU1-PBR Option)

In addition to data connections, all Bus customer units also provide conventional
digital inputs and outputs.

By means of a relay contact, brake control and even warnings to another system
can be initiated.

The digital input has a 2.5V switching threshold for the evaluation of the
temperature sensor. The input can, however, also be used for an emergency stop
function.

All BUS switching components have the same basic design. However, the
Profibus Option has an RTS signal output on connector X6.3.83 in addition to the
data leads. In addition, the Profibus module also has a second set of data
connections (X6.4) and a DIP switch for the termination resistors at the front.

Note:

Further details can be found in the applicable operating instructions for the
Bus systems,
Profibus

BU 0020 DE, CANnord

BU 0060 DE, USS

BU 0050 DE

Note:

The BUS customer units include two SK8 shielding clips which can be used
to provide a better shielding connection of the bus cable to the shield angle of
the SK 700E.

USS

SK CU1-USS

CAN

SK CU1-CAN

CAN RJ

SK CU1-CAN-RJ

Profibus

SK CU1-PBR

Functions

Maximum cross-

section

X4.1

X5.1

X7.1

X6.1

Output relay

1.5 mm

2

X4.2

X5.2

X7.2

X6.2

Digital input

1.5 mm

2

X4.3

X5.3

RJ45

X6.3

Data leads

1.5 mm

2

/ RJ45

--

--

RJ45

X6.4

Data leads, parallel

1.5 mm

2

/ RJ45
























NOTE: All control voltages are based on a common reference potential!

Potentials AGND /0V und GND /0V are internally linked in the device.

The maximum total current 5/15V is 300mA!

Data leads for the Bus system used:

e.g. Profibus (Kl. 81-82-83, PROFI A/B)
or RS485 (Kl. 73-74, RS485 +/-)
or CAN (Kl. 75-76, CAN1 H/L)

Output of PLC: 2,5 ... 33V

Output relay:
Max. 2,0A
28V DC /230 V AC

Digital input 1 (P420)

Power supply: 5V

Power supply: 15V

Terminal 83‚"RTS", X6.4 and 2x
termination resistor only available
with Profibus module!

Only Profibus has the DIP switch for the
termination resistor at this position!

X

6

.1

X

6

.2

X

6

.3

01 REL1.1

02 REL1.2

47 PBR +5V

48 PBR 0V

81 PBR A

82 PBR B

40 GND / 0V

41 VO +5V

83 PBR RTS

X

6

.4

81 PBR A

82 PBR B

90 SHIELD

21 DIG IN 1

42 VO +15V

RTA

RTB

Only internal 5V
power supply
- do not use -

WARNING / NOTE

It is not permissible to connect the output relay of the Customer Unit (SK CU...and SK XU) to dangerous
voltages(

≥60VAC) if a contact of the relay is connected to a circuit with safe isolation.

USS

CAN

Termination resistor (CAN/USS)

not switched on

switched on

ON OFF