3.3 Special extension unit

BU 0700 GB-1411

Subject to technical alterations

53

Different position of the special extension unit, for devices > 22 kW:

WARNING / NOTE

Installation must be carried out by qualified personnel only, paying particular attention to safety and
warning instructions.
Customer units must not be inserted/removed when live.

The procedure is as above, however no locking lever is present.
The module engages when pushed in.

... Different removal of special extension units in devices > 22 kW:

As shown, simply lever out from the upper edge.

Ensure that the mains voltage is switched off and that sufficient
waiting time has expired.

Note:

Following the insertion, replacement or removal of modules, and
once the equipment has been switched on again, this procedure
is indicated with the message E017 Customer unit changed.

Getriebebau NORD

GmbH & Co. KG
D-22941 Bargteheide / Germany

Typ/Part-No: SK_XU1_POS 7820055/10C195890

Input: 6 x digital 15V / 24V
Output: 2 x relay 5A 250V~/AC1
Interface: 1 x encoder A,B,N RS422
1 x SSI DAT/CLK RS422

X10.1

X10.2

X10.3

5

DIG

IN 1

6

DIG

IN 2

7

DIG

IN 3

8

DIG

IN 4

1

1

+15

V

1

RE

L

1.

1

2

RE

L

1.

2

3

RE

L

2.

1

4

RE

L

2.

2

9

DIG

IN 3

1

0

DIG

IN 4

1

2

0V

/

G

ND

1

3

S

S

I CL

K

+

1

4

S

S

I CL

K

-

1

5

S

S

I DA

T

+

1

6

S

S

I DA

T

-

1

7

+5V

1

8

0V

/

G

ND

1

9

S

P

UR A

+

2

0

S

P

UR A

-

2

3

S

P

UR N+

2

1

S

P

UR B

+

2

2

S

P

UR B

-

2

4

S

P

UR N-

X10.3

Getriebebau NORD

GmbH & Co. KG
D-22941 Bargteheide / Germany

Typ/Part-No/ID: SK_CU1_MLT 7820051/10C195890

Input: 2 x analog -10...10V / 0...20mA
6 x digital 15V / 24V
Output: 2 x analog 0...10V
2 x relay 5A 250V~/AC1

X2.1

X2.2

X2.3

1

1

V

R

E

F 1

0

V

1

2

A

G

N

D

/0

V

1

4

A

IN

1

+

1

6

A

IN

2

+

1

7

A

O

U

T1

2

1

D

IG

I

N

1

2

2

D

IG

I

N

2

2

3

D

IG

I

N

3

2

4

D

IG

I

N

4

4

2

V

O

+

1

5

V

1

R

E

L

1

.1

2

R

E

L

1

.2

3

R

E

L

2

.1

4

R

E

L

2

.2

2

5

D

IG

I

N

5

2

6

D

IG

I

N

6

1

8

A

O

U

T2

4

1

V

O

+

5

V

4

0

G

N

D

/0

V

0

/4

..

.2

0

m

A

(

ON

)

AIN 1

-1

0

/0

..

.1

0

V

(

OFF)

0

/4

..

.2

0

m

A

(

ON

)

AIN 2

-1

0

/0

..

.1

0

V

(

OFF)

Customer

unit

Special

extension unit

Getriebebau NORD

GmbH & Co. KG
D-22941 Bargteheide / Germany

Typ/Part-No: SK_XU1_POS 7820055/10C195890

Input: 6 x digital 15V / 24V
Output: 2 x relay 5A 250V~/AC1
Interface: 1 x encoder A,B,N RS422
1 x SSI DAT/CLK RS422

X10.1

X10.2

X10.3

5

DIG

IN 1

6

DIG

IN 2

7

DIG

IN 3

8

DIG

IN 4

1

1

+15

V

1

RE

L

1.

1

2

RE

L

1.

2

3

RE

L

2.

1

4

RE

L

2.

2

9

DIG

IN 3

1

0

DIG

IN 4

1

2

0V

/

G

ND

1

3

S

S

I CL

K

+

1

4

S

S

I CL

K

-

1

5

S

S

I DA

T

+

1

6

S

S

I DA

T

-

1

7

+5V

1

8

0V

/

G

ND

1

9

S

P

UR A

+

2

0

S

P

UR A

-

2

3

S

P

UR N+

2

1

S

P

UR B

+

2

2

S

P

UR B

-

2

4

S

P

UR N-

X10.3

Getriebebau NORD

GmbH & Co. KG
D-22941 Bargteheide / Germany

Typ/Part-No/ID: SK_CU1_MLT 7820051/10C195890

Input: 2 x analog -10...10V / 0...20mA
6 x digital 15V / 24V
Output: 2 x analog 0...10V
2 x relay 5A 250V~/AC1

X2.1

X2.2

X2.3

1

1

V

R

E

F 1

0

V

1

2

A

G

N

D

/0

V

1

4

A

IN

1

+

1

6

A

IN

2

+

1

7

A

O

U

T1

2

1

D

IG

I

N

1

2

2

D

IG

I

N

2

2

3

D

IG

I

N

3

2

4

D

IG

I

N

4

4

2

V

O

+

1

5

V

1

R

E

L

1

.1

2

R

E

L

1

.2

3

R

E

L

2

.1

4

R

E

L

2

.2

2

5

D

IG

I

N

5

2

6

D

IG

I

N

6

1

8

A

O

U

T2

4

1

V

O

+

5

V

4

0

G

N

D

/0

V

0

/4

..

.2

0

m

A

(

ON

)

AIN 1

-1

0

/0

..

.1

0

V

(

OFF)

0

/4

..

.2

0

m

A

(

ON

)

AIN 2

-1

0

/0

..

.1

0

V

(

OFF)

Customer

unit

Special

extension unit

Advertising