Parameter

Setting value / Description / Note

Available with option

P544 (P)

Bus actual value 2

always visible

0 ... 12

[ 0 ]

This parameter is identical to P543.
Condition is PPO 2 or PPO 4 type (P507).

P545 (P)

Bus actual value 3

always visible

0 ... 12

[ 0 ]

This parameter is identical to P543.
Condition is PPO 2 or PPO 4 type (P507).
Note: For the selection (P546 = {3} or {6} (32 Bit setpoint position) (P454) is not available.

P546 (P)

Function bus setpoint 1

POS

0 ... 7

[ 1 ]

In this parameter, a function is allocated to the output setpoint 1 during bus actuation.

Note: Further details can be found in the respective BUS instruction manuals.

0 = Off
1 = Setpoint frequency (16 Bit)
2 = 16 Bit setpoint position (only with Option PosiCon, SK 700E)
3 = 32 Bit setpoint position (only with Option PosiCon, SK 700E and when PPO type 2 or 4 has been

selected)

4 = Control terminals PosiCon (only with Option PosiCon, SK 700E, 16Bit)
5 = Setpoint position (16 Bit) increment 2 (only with PosiCon SK 700E)
6 = Setpoint position (32 Bit) increment 2 (only with PosiCon SK 700E)
7 = Bus IO In Bits 0-7

P547 (P)

Function bus setpoint 2

always visible

0 ... 20

[ 0 ]

In this parameter, a function is allocated to the output setpoint 2 during bus actuation.
NOTE:

Further details can be found in the respective BUS operating instructions or in the
description of P400.

0 = Off

1 = Setpoint frequency

2 = Torque current limit

3 = Actual frequency PID

4 = Frequency addition

5 = Frequency subtraction

6 = Current limit

7 = Maximum frequency

8 = Actual PID frequency limited

9 = Actual PID frequency monitored

10 = Torque

11 = Torque precontrol

12 = Control terminals PosiCon (with PosiCon option only)

13 = Multiplication

14 = Process controller actual value

15 = Setpoint process controller

16 = Process controller precontrol

17 = Bus IO In Bits 0-7

18 = Curve travel calculator

19 = Set relay (P541)

20 = Set analog output (P542)

P548 (P)

Function bus setpoint 3

always visible

0 ... 20

[ 0 ]

This parameter is identical to P547. It is only present when P546

3.

P549

Pot Box Function

always visible

0 ... 13

[ 1 ]

In this parameter, a function is assigned to the potentiometer value output when control is via the
potentiometer option. (An explanation can be found in the description of P400)

0 = Off

1 = Setpoint frequency

2 = Torque current limit

3 = Actual frequency PID

4 = Frequency addition

5 = Frequency subtraction

6 = Current limit

7 = Maximum frequency

8 = PID limited current frequency

9 = PID supervised current frequency

10 = Servo-ModeTorque

11 = Pre-tension torque

12 = No function

13 = Multiplication