1 technology unit – NORD Drivesystems BU0700 User Manual

Page 22

Advertising
background image

NORDAC SK 700E Operating Manual

22

Subject to technical alterations

BU 0700 GB-1411

700E

N O R D A C

700E

N O R D A C

3.1 Technology unit

(Technology Unit, Option)

Technology units are snapped onto the inverter externally. They are for the control or parameterisation of the inverter and for
the display of current operating settings..

Technology unit

(SK TU1-...)

Description

Data

ParameterBox

SK TU1-PAR

For text-driven initialisation, parameterisation, configuration

and control of the frequency inverter. Background illuminated

graphic display.

6 languages

Storage of 5 data sets

Help texts

ControlBox

SK TU1-CTR

Used for commissioning, parameterisation, configuration and

control of the frequency inverter.

4-figure, 7-segment

LED display

Potentiometer

SK TU1-POT

For direct control of the drive from the frequency converter.

Potentiometer 0 to 100%

ON / OFF / Reverse button

CANbus module

SK TU1-CAN

This option enables control of the SK 700E via the CANbus

serial port.

Baud rate: 500 KBit/s

Connector: Sub-D 9

Profibus module

SK TU1-PBR

This option enables control of the SK 700E via the Profibus

DP serial port.

Baud rate: 1.5 MBaud

Connector: Sub-D 9

Profibus module

SK TU1-PBR-24V

This option enables control of the SK 700E via the Profibus

DP serial port. Operation requires an external 24V supply.

Baud rate: 12 MBaud

Connector: Sub-D 9

ext. +24V DC supply

RS 232

SK TU1-RS2

This option enables control of the SK 700E via the RS 232

serial port, e.g. using a PC.

Connector: Sub-D 9

CANopen module

SK TU1-CAO

This option enables control of the SK 700E via the CANbus

serial port, using the CANopen protocol

Baud rate: up to 1 MBit/s

Connector: Sub-D 9

DeviceNet module

SK TU1-DEV

This option enables control of the SK 700E via the DeviceNet

serial port using the DeviceNet protocol.

Baud rate: 500 KBit/s

5-pin screw connector

InterBus module

SK TU1-IBS

This option enables control of the SK 700E via the InterBus

serial port.

Baud rate: 500 kBit/s (2Mbit/s)

Connector: 2 x Sub-D 9

AS interface

SK TU3-AS1

Actuator-sensor interface is a bus system for the lower field

bus level, used for simple control tasks.

4 sensors / 2 actuators 5 / 8 pin

screw connector

Mounting

The technology units must be installed as
follows:

1. Switch off the mains voltage,

observe the waiting period.

2.

Remove the blanking cover by
pressing the upper and lower
catches

.

3. Allow the technology unit to engage

audibly by pressing lightly on the
installation surface.







WARNING / NOTE

Modules must not be inserted or removed unless the device is free of voltage. The slots may only be used
for the applicable modules.

Installation of a technology unit separate from the frequency inverter is not possible. It must be connected
directly to the frequency inverter.

Advertising