NORD Drivesystems BU0700 User Manual

Page 42

Advertising
background image

NORDAC SK 700E Operating Manual

42

Subject to technical alterations

BU 0700 GB-1411

Motor temperature protection

- applies to all customer units! -

For secure protection against motor overheating, a temperature sensor (PTC
thermistor (PTC, PTC) can be connected to any digital input (excluding multi-I/O).

The appropriate parameters (P420 ... P423 or P425, depending on option) must be
set to a value of 13 (PTC thermistor input) for this purpose.

NOTE: With multi I/O only digital input 6 (P425) is possible!

The supply voltage varies dependent upon the customer unit. The lowest voltage
possible should be chosen.

Internal switching in the inverter prevents excessive PTC voltage.

The cable routing should always be separate from the motor cable and with
shielded cables.

Installation of the customer unit:

WARNING / NOTE

Installation must be carried out by qualified personnel only, paying particular attention to safety and warning
instructions.
Customer units must not be inserted/removed when live.

1. Switch off the mains voltage, observe the waiting period.

2. Remove the cover grid from the connection area by loosening the 2 screws and

levering out the device cover (slot, see Fig.) or simply pull it out.

3. Move the locking lever to the "open" position.

4. Using light pressure, push the customer unit into the upper guide rail until it

engages and lies flush with the plastic frame.

5. Move the locking lever to the "closed" position.

6. Remove the connector by pressing the releases then make the necessary

connections. Then insert the connectors until they engage.

7. Replace all covers.

CLOSED

OPEN

Locking device closed

Locking device open

Customer unit

Locking pin

Technology unit

Special extension unit

Motor
PTC

Supply voltage +5V

Digital input

Advertising