HP XP P9500 Storage User Manual

Page 154

Advertising
background image

5.

Register a command device for the forward direction in the storage systems of the primary
and intermediate sites.

This creates the command device definition file.

For details on how to register a command device in a storage system, see

“Registering a

command device in a storage system” (page 568)

.

6.

Perform a remote scan at the storage system of the intermediate site.

Perform a scan over a range that contains volumes to be defined in the copy group.

This creates disk configuration definition file for the intermediate site.

For details on how to perform a scan to acquire hardware information, see

“Acquiring volume

information” (page 518)

.

7.

Establish an inter-disk controller logical path (Intermediate

→ Remote).

Establishing an inter-disk controller logical path is part of creating the path set definition file.

8.

Register a command device for the forward direction in the storage system of the remote site.

154 Configuration definitions