However, step 1 is different. From the intermediate site, execute the YKDELETE command for the
Continuous Access Journal Z copy pair between the intermediate site and the remote site.

Recovering

For details about the recovering procedure required when a path failure occurs between the storage
systems at the primary site and the intermediate site, see the recovery procedure used when a
nonvolatile failure occurs in the intermediate site storage system. For details, see

“Recovering”

(page 346)

in

“Operating procedure during an intermediate site storage system failure (nonvolatile)”

(page 345)

.

However, there is no need to perform step 2.

Operating procedure during a path failure between the storage systems at the
intermediate site and the remote site

The following are the operating procedures that must be performed when a path failure occurs
between the storage systems at the intermediate site and the remote site.

Preparing

If a path failure occurs between the storage systems at the intermediate site and the remote site,
perform the same preparatory procedure that is used when a nonvolatile failure occurs in the
remote site storage system. See

“Preparing” (page 349)

in

“Operating procedure during a remote

site storage system failure (nonvolatile)” (page 349)

.

Recovering

If a path failure occurs between the storage systems at the intermediate site and the remote site,
perform the same recovery procedure that is used when a nonvolatile failure occurs in the remote
site storage system. See

“Recovering” (page 350)

in

“Operating procedure during a remote site

storage system failure (nonvolatile)” (page 349)

.

Using a 3DC Multi-Target (Cnt Ac-J Z x Cnt Ac-J Z) configuration

The following table explains how to perform maintenance for a 3DC Multi-Target (Cnt Ac-J Z x Cnt
Ac-J Z) configuration and how to take action if a failure occurs.

For maintenance or troubleshooting for the primary site storage system, either of the two remote
sites can be selected as the failover destination. If a primary site storage system failure occurred,
you can view the consistency time of each Continuous Access Journal Z copy pair to select the site
that has the latest data update time as the failover destination.

Table 101 Using a 3DC Multi-Target (Cnt Ac-J Z x Cnt Ac-J Z) configuration

See:

Description

Target

Maintenance
or failure

No.

“Performing
primary site

Create a Continuous Access Journal Z copy
pair between remote sites 1 and 2, and then

Primary site storage system maintenance

Maintenance

1

storage system

change the configuration to a 2DC

maintenance”
(page 355)

configuration (Remote 1

→ Remote 2, or

Remote 2

→ Remote 1).

“Performing
storage system

Suspend the Continuous Access Journal Z
copy pair between the primary site and the

Storage system maintenance for remote site
1 or remote site 2

2

maintenance

maintenance-target remote site, and then

for remote site

change the configuration to a 2DC

1 or 2”
(page 361)

configuration consisting of the primary site
and the other remote site.

“Performing
primary site

Delete the Continuous Access Journal Z copy
pair between the primary site and the remote

Primary site host maintenance

3

host

site that is not the failover destination, and

Using a 3DC Multi-Target (Cnt Ac-J Z x Cnt Ac-J Z) configuration 353