Table 50 Required Configuration Files (3DC Multi-Target (Cnt Ac-S Z x Cnt Ac-J Z)

Configuration) (continued)

Remarks

Description

Item

The route list defined for a 3DC
Multi-Target (Cnt Ac-S Z x Cnt Ac-J Z)

Route list definition file
and command device
definition file

configuration must differ from that for a
3DC Cascade (Cnt Ac-S Z x Cnt Ac-J Z)
configuration for failover and failback.
Prepare the following route lists by
referring to

Table 51 (page 173)

:

Route list that is required when all
sites are available

Route list used when a failure occurs
at a site (recommended)

This item is not necessary if you use
Remote Web Console to set up logical
paths.

The following path sets are required for
logical paths.

Path set definition file

An inter-control unit logical path is
required between the primary site and
the local site (for both directions).

An inter-disk controller logical path is
required between the primary site and
the remote site (for both directions).

The following table describes the route list necessary for operation in a 3DC Multi-Target (Cnt Ac-S
Z x Cnt Ac-J Z) configuration.

Table 51 Required route list (3DC Multi-Target (Cnt Ac-S Z x Cnt Ac-J Z) configuration)

Route list needed in Business Continuity Manager

Remote site
condition

Local site
condition

Primary site
condition

Host on which Business
Continuity Manager is
started

Primary

→ Local

Usable

Usable

Usable

Primary host

Primary

→ Remote

Primary

→ Local

Unusable

Usable

Usable

Primary

→ Remote

Usable

Unusable

Usable

Primary

#

Unusable

Unusable

Usable

Local

→ Primary → Remote

Usable

Usable

Usable

Local host

Local

→ Primary

Unusable

Usable

Usable

Local

→ Remote

Usable

Usable

Unusable

Local

#

Local

#

Unusable

Usable

Unusable

Remote

→ Primary → Local

Usable

Usable

Usable

Remote host

Remote

→ Primary

Usable

Unusable

Usable

None

Usable

Usable

Unusable

Usable

Unusable

Unusable

Legend:

Usable: The target site can be used.

Unusable: The target site cannot be used because of an error.