Performing primary site storage system maintenance, Failover, Performing primary site storage system – HP XP P9500 Storage User Manual

Page 474

Advertising
background image

Table 107 Using a 4x4x4 Cascade Configuration (continued)

See

Description

Target

Maintenance or
Failure

Number

“Operating procedure
during a primary site
host failure” (page 508)

Perform a reverse
resync for Continuous
Access Synchronous Z

Primary site host
failure

13

copy pairs, and then
change the
configuration to a
4x4x4 Multi-Target
configuration in which
operation is performed
from the intermediate
site.

“Operating Procedure
During a Path Failure

Suspend Continuous
Access Synchronous Z

Path failure between
the Primary

14

between the Primary

copy pairs by using

Intermediate storage
systems

Site Storage System

the Continuous Access

and the Intermediate

Synchronous Z

Site Storage System”
(page 512)

Consistency
Preservation function,
and then
resynchronize them.

Performing Primary Site Storage System Maintenance

The following are the procedures for performing primary site storage system maintenance.

Failover

1.

Stop operation at the primary site.

2.

From the intermediate site, execute the YKSUSPND REVERSE command for the Continuous
Access Synchronous Z copy group container.

474

Maintenance and troubleshooting operations

Advertising