Introduction and Safety

Personnel requirements

These are the personnel requirements for Ex-approved products in potentially explosive
atmospheres:

• All work on the product must be carried out by certified electricians and ITT-authorized

mechanics. Special rules apply to installations in explosive atmospheres.

• All users must know about the risks of electric current and the chemical and physical

characteristics of the gas, the vapor, or both present in hazardous areas.

• Any maintenance for Ex-approved products must conform to international and national

standards (for example, IEC/EN 60079-17).

ITT disclaims all responsibility for work done by untrained and unauthorized personnel.

Product and product handling requirements

These are the product and product handling requirements for Ex-approved products in
potentially explosive atmospheres:

• Only use the product in accordance with the approved motor data.

• The Ex-approved product must never run dry during normal operation. Dry running during

service and inspection is only permitted outside the classified area.

• Before you start work on the product, make sure that the product and the control panel are

isolated from the power supply and the control circuit, so they cannot be energized.

• Do not open the product while it is energized or in an explosive gas atmosphere.

• Make sure that thermal contacts are connected to a protection circuit according to the

approval classification of the product, and that they are in use.

• Intrinsically safe circuits are normally required for the automatic level-control system by the

level regulator if mounted in zone 0.

• The yield stress of fasteners must be in accordance with the approval drawing and the

product specification.

• Do not modify the equipment without approval from an authorized ITT representative.

• Only use parts that are provided by an authorized ITT representative.

Product approval standards

Regular standards

All standard products are approved according to CSA standards in Canada and UL standards
in USA. The drive unit degree of protection follows IP68. See the nameplate for maximum
submersion, according to standard IEC 60529.
All electrical ratings and performance of the motors comply with IEC 600341.

Explosion-proofing standards

All explosion-proof products for use in explosive atmospheres are designed in compliance with
one or more of the following approvals:

• EN, ATEX Directive 94/9/EC

• FM According to NEC

• Class 1 Div 1 Groups “C”, and “D”

• Class 2 Div 1 Groups “E”, “F”, and “G”

• Class 3 Div 1 Hazardous Locations

ATEX/IECEx:

• Group: IIC

• Category: Ex ia

• Temperature Class: T4 (for ambients up to 100ºC)

• ATEX Marking: Ex II 1 G