Suction-piping checklist – Goulds Pumps 3196 i-FRAME - IOM User Manual

Page 38

Advertising
background image

Installation

Fastening

WARNING:

• Only use fasteners of the proper size and material.
• Replace all corroded fasteners.
• Make sure that all fasteners are properly tightened and that there are no missing fasteners.

Suction-piping checklist

Performance curve reference

Net positive suction head available (NPSH

A

) must always exceed NPSH required (NPSH

R

) as

shown on the published performance curve of the pump.

Suction-piping checks

Check

Explanation/comment

Checked

Check that the distance be-

This minimizes the risk of cavi-

tween the inlet flange of the

tation in the suction inlet of the

pump and the closest elbow is pump due to turbulence.
at least five pipe diameters.

See the Example sections for
illustrations.

Check that elbows in general

See the Example sections for

do not have sharp bends.

illustrations.

Check that the suction piping

The suction piping must never

is one or two sizes larger than have a smaller diameter than
the suction inlet of the pump.

the suction inlet of the pump.

Install an eccentric reducer be- See the Example sections for
tween the pump inlet and the

illustrations.

suction piping.
Check that the eccentric re-

See the example illustrations.

ducer at the suction flange of
the pump has the following
properties:
• Sloping side down
• Horizontal side at the top
If suction strainers or suction

Suction strainers help to pre-

bells are used, check that they vent clogging.
are at least three times the

Mesh holes with a minimum

area of the suction piping.

diameter of 1/16 in. (1.6 mm)
are recommended.

If more than one pump oper-

This recommendation helps

ates from the same liquid

you to achieve a higher pump

source, check that separate

performance.

suction-piping lines are used
for each pump.
If necessary, make sure that

the suction piping includes a
drain valve and that it is cor-
rectly installed.

Liquid source below the pump

Check

Explanation/comment

Checked

Make sure that the suction pip- This helps to prevent the oc-
ing is free from air pockets.

currence of air and cavitation
in the pump inlet.

Check that the suction piping

slopes upwards from the liquid
source to the pump inlet.

36

Model 3196 i-FRAME Installation, Operation, and Maintenance Manual

Advertising