Check

Explanation/comment

Checked

If the pump is not self-priming, Use a foot valve with a diame-
check that a device for priming ter that is at least equivalent to
the pump is installed.

the diameter of the suction
piping.

Liquid source above the pump

Check

Explanation/comment

Checked

Check that an isolation valve is This permits you to close the
installed in the suction piping

line during pump inspection

at a distance of at least two

and maintenance.

times the pipe diameter from

Do not use the isolation valve

the suction inlet.

to throttle the pump. Throttling
can cause these problems:
• Loss of priming
• Excessive temperatures
• Damage to the pump
• Voiding the warranty

Make sure that the suction pip- This helps to prevent the oc-
ing is free from air pockets.

currence of air and cavitation
in the pump inlet.

Check that the piping is level

or slopes downward from the
liquid source.
Make sure that no part of the

suction piping extends below
the suction flange of the pump.
Make sure that the suction pip- This prevents air from entering
ing is adequately submerged

the pump through a suction

below the surface of the liquid vortex.
source.

Example: Elbow close to the pump suction inlet

Correct

Incorrect

The correct distance between the inlet flange
of the pump and the closest elbow must be at
least five pipe diameters.

1. Enough distance to prevent cavitation
2. Eccentric reducer with a level top

Model 3196 i-FRAME Installation, Operation, and Maintenance Manual