Installation

Piping guidelines

Guidelines for piping are given in the Hydraulic Institute Standards available from the Hydraulic
Institute at 9 Sylvan Way, Parsippany, NJ 07054-3802. You must review this document before
you install the pump.

Checklist

Check

Explanation/comment

Checked

Check that all piping is sup-

This helps to prevent:

ported independently of, and

• Strain on the pump

lined up naturally with, the

• Misalignment between the pump and the drive

pump flange.

unit

• Wear on the pump bearings and the coupling
• Wear on the pump bearings, seal, and shafting

Keep the piping as short as

This helps to minimize friction losses.

possible.
Check that only necessary fit- This helps to minimize friction losses.
tings are used.
Do not connect the piping to

the pump until:
• The grout for the baseplate

or sub-base becomes hard.

• The hold-down bolts for the

pump and the driver are
tightened.

Make sure that all the piping

This prevents air from entering the piping system

joints and fittings are airtight.

or leaks that occur during operation.

If the pump handles corrosive —
fluids, make sure that the pip-
ing allows you to flush out the
liquid before you remove the
pump.
If the pump handles liquids at This helps to prevent misalignment due to linear
elevated temperatures, make expansion of the piping.
sure that the expansion loops
and joints are properly in-
stalled.

Example: Installation for expansion

Correct

Incorrect

1. Expansion loop/joint