Discharge piping checklist – Goulds Pumps 3196 i-FRAME - IOM User Manual

Page 40

Advertising
background image

Installation

Example: Suction piping equipment

Correct

Incorrect

1. Suction pipe sloping upwards from liquid

1. Air pocket, because the eccentric reducer

source

is not used and because the suction piping

2. Long-radius elbow

does not slope gradually upward from the

3. Strainer

liquid source

4. Foot valve
5. Eccentric reducer with a level top

Discharge piping checklist

Checklist

Check

Explanation/comment

Checked

Check that an isolation valve is

The isolation valve is required for:

installed in the discharge line.

• Priming
• Regulation of flow
• Inspection and maintenance of the pump
See Example: Discharge piping equipment for
illustrations.

Check that a check valve is in-

The location between the isolation valve and

stalled in the discharge line, be-

the pump allows inspection of the check valve.

tween the isolation valve and the

The check valve prevents damage to the

pump discharge outlet.

pump and seal due to the back flow through
the pump, when the drive unit is shut off. It is
also used to restrain the liquid flow.
See Example: Discharge piping equipment for
illustrations.

If increasers are used, check that

See Example: Discharge piping equipment for

they are installed between the

illustrations.

pump and the check valve.
If quick-closing valves are installed This protects the pump from surges and water
in the system, check that cushion- hammer.
ing devices are used.

38

Model 3196 i-FRAME Installation, Operation, and Maintenance Manual