Maintenance

3. Remove the seal chamber (184).

4. Remove the shaft sleeve (126) if it is used.

The mechanical seal is attached to the sleeve.

NOTICE:Be careful with the stationary portion of the mechanical seal that is either clamped
between the backplate and the gland or seated in the seal-chamber bore. Failure to do so
may result in equipment damage.

5. Remove the rotary portion of the seal from the sleeve by loosening the setscrews and

sliding it off the sleeve.
Refer to the mechanical-seal instructions for more information.

6. Remove the gland (250), the stationary portion of the seal, and the O-ring (360Q).

Remove the stuffing-box cover (3196, CV 3196, HT 3196, LF 3196, 3796)

1. Remove the gland nuts (355) and the gland (107).
2. Remove the stuffing-box-cover nuts (370H).

72

Model 3196 i-FRAME Installation, Operation, and Maintenance Manual