Maintenance

This figure shows the areas to inspect for wear on the bearing frame inside surface.

Figure 21: Inside surface inspection locations

C-face adapter inspection

Checklist

• Visually inspect the C-face adapter (340) for cracks.

• Check all surfaces for rust, scale, or debris and remove all loose and foreign material.

• Check for corrosion or pitting.

This figure shows the areas to inspect for cracks on the C-face adapter.

Figure 22: C-face adapter inspection locations

Seal chamber and stuffing box cover inspection

Checklist

Perform these checks when you inspect the seal chamber and stuffing box cover:

• Make sure that these surfaces are clean:

• Seal chamber and stuffing box cover

• Dynamic-seal backplate gasket

• Mounting

• Make sure there is no pitting or wear greater than 1/8 in. (3.2 mm) deep.

Replace the seal chamber and stuffing box cover if pitting or wear exceeds this
measurement.

• Inspect the machined surfaces and mating faces noted in the figures.

These images point to the areas to inspect:

Model 3196 i-FRAME Installation, Operation, and Maintenance Manual