Lubrication conversion, Frame lubrication conversion – Goulds Pumps 3196 i-FRAME - IOM User Manual

Page 129

Advertising
background image

Maintenance

Description

Model 3196 MTi
1–3/4 in. Shaft
Dia. Max BHP-
122 HP

Model 3196 LTi
2–1/8 in. Shaft
Dia. Max BHP-
200 HP

Model 3196
XLT-i 2–1/2 in.
Shaft Dia. Max
BHP-250 HP
17 in. XLT-i has
2–3/4 in. Shaft
Dia. Max BHP-
350 HP

Lubrication conversion

Frame lubrication conversion

NOTICE:

• Never mix greases of different consistencies (NLGI 1 or 3 with NLGI 2) or with different

thickeners. For example, never mix a lithium-based grease with a polyurea-based grease.
Doing so may result in decreased performance.

• Remove the bearings and old grease if you need to change the grease type or

consistency. Failure to do so may result in equipment damage or decreased performance.

Use a grease that is suitable for high temperatures when you have frame pumpage
temperatures greater than 350°F (177°C). Ensure that mineral-oil greases have oxidation
stabilizers and a consistency of NLGI 3.

Table 23: Lubricating-grease requirements
Most pumps use Sunoco 2EP grease. High temperature units with a pumpage temperature greater than
350° F (177°C) use Mobil SCH32.