Maintenance

a) Install a seal-chamber cover or a backplate (184) and fasten with nuts (370H) with .

b) Check the seal-chamber cover runout.

Rotate the indicator through 360º. If the total indicator reading is greater than 0.005
inches (0.13 mm), determine the cause and correct the issue before you proceed.

Model 3196 i-FRAME Installation, Operation, and Maintenance Manual