Commissioning, Startup, Operation, and Shutdown

1. Driver
2. Pump end plate
3. Bearing housing
4. Jam nut

3. Put the pump-half of the coupling guard in place:

a) Slightly spread the bottom apart.
b) Place the coupling guard half over the pump-side end plate.

1. Annular groove
2. Pump-side end plate
3. Driver
4. Pump half of the coupling guard

The annular groove in the coupling guard half must fit around the end plate.

Model 3196 i-FRAME Installation, Operation, and Maintenance Manual

47