Guidelines for i-alert™ condition monitor disposal, Disassemble the c-face adapter – Goulds Pumps 3196 i-FRAME - IOM User Manual

Page 87

Advertising
background image

Maintenance

2. For the MTi and LTi models, remove the bearing frame foot-to-frame bolts (370F) and the

frame foot (241).

Guidelines for i-ALERT™ Condition Monitor disposal

Precautions

WARNING:

• Never heat the condition monitor to temperatures in excess of 300°F (149°C). Heating to these

temperatures could result in death or serious injury.

• Never dispose of the condition monitor in a fire. This could result in death or serious injury.

Guidelines

The battery contained in the condition monitor does not contain enough lithium to qualify as
reactive hazardous waste. Use these guidelines when disposing of the condition monitor.

• The condition monitor is safe for disposal in the normal municipal waste stream.

• Adhere to local laws when you dispose of the condition monitor.

Disassemble the C-face adapter

NOTICE:You must properly support the motor with a clean, uncorroded eye bolt or a strap
under both end bells. Failure to do so may result in equipment damage.

1. Loosen the motor-mounting bolts and remove the motor.

Table 12: Required number of motor-mounting bolts
This table shows the number of motor-mounting bolts.

Pump frame

Motor frame

Number of bolts

STi

All

4

MTi and LTi

143-286

4

324-365

8

2. Loosen the bolts attached to the bearing-frame flange and remove the C-face adapter from

the bearing frame.

Model 3196 i-FRAME Installation, Operation, and Maintenance Manual

85