Commissioning, Startup, Operation, and Shutdown

These parts are included with the pump in the box of fittings. Before you start the pump, you
must install the packing, lantern ring, and split gland according to the Packed stuffing box
maintenance section in the Maintenance chapter.

Connection of sealing liquid for a packed stuffing box

WARNING:
Packed stuffing boxes are not allowed in an ATEX-classified environment.

NOTICE:
Make sure to lubricate the packing. Failure to do so may result in shortening the life of the
packing and the pump.

You must use an external sealing liquid under these conditions:

• The pumped fluid includes abrasive particles.

• The stuffing-box pressure is below atmospheric pressure when the pump is running with a

suction lift or when the suction source is in a vacuum. Under these conditions, packing is
not cooled and lubricated and air is drawn into pump.

Conditions for application of an external liquid

Condition

Action

The stuffing box pressure is above atmospheric

Normal gland leaks of 40 to 60 drops per minute is

pressure and the pumped fluid is clean.

usually sufficient to lubricate and cool the packing.
You do not need sealing liquid.

The stuffing box pressure is below atmospheric

An outside source of clean compatible liquid is

pressure or the pumped fluid is not clean.

required.

An outside source of clean compatible liquid is

You must connect the piping to the lantern ring

required.

connection with a 40 to 60 drops-per-minute leak
rate. The pressure must be 15 psi (1.01 kg/cm

2

)

above the stuffing box pressure.

Dynamic-seal option

WARNING:
Dynamic seals are not allowed in an ATEX-classified environment.

The dynamic seal consists of two parts:

• Repeller seal

• Secondary seal (one of the following):

• Graphite packing

• Elastomenic face seal

Table 9: Dynamic seal part function

Part

Function

Repeller seal

A repeller seal prevents liquid from entering the stuffing box during
operation. The repeller normally does not require a flush. However, for
services that allow a build-up of solids on the repeller, you must install a
flush connection. If a danger of freezing exists, then you must install a drain
connection to drain the repeller chamber.