Product Description
Part description 3196
Figure 6: 3196 part description
Table 3: Casing
This table describes the pump casing parts.
Part
Description
Discharge
Top-centerline
Casing ventilation
Self venting
Gasket
Fully confined
Mounting method
Integral foot support for maximum resistance to misalignment due to piping loads.
Standard flange
ANSI flat-faced serrated flange
Optional flanges
One of the following flanges can be used:
• ANSI class 150 raised-face serrated flange
• ANSI class 300 flat-face serrated flange
• ANSI class 300 raised-face serrated flange
Impeller
The impeller is
• fully open
• screwed onto the shaft
The threads are sealed from the pumped liquid by a Teflon O-ring for the 3196.
Cover
Standard seal
• The 3196 is available with a stuffing-box cover designed for a packing and a BigBore or a
TaperBore PLUS seal chamber.
Optional seal
14