Product Description

Part description 3196

Figure 6: 3196 part description

Table 3: Casing
This table describes the pump casing parts.

Part

Description

Discharge

Top-centerline

Casing ventilation

Self venting

Gasket

Fully confined

Mounting method

Integral foot support for maximum resistance to misalignment due to piping loads.

Standard flange

ANSI flat-faced serrated flange

Optional flanges

One of the following flanges can be used:

• ANSI class 150 raised-face serrated flange
• ANSI class 300 flat-face serrated flange
• ANSI class 300 raised-face serrated flange

Impeller

The impeller is

• fully open

• screwed onto the shaft

The threads are sealed from the pumped liquid by a Teflon O-ring for the 3196.

Cover

Standard seal

• The 3196 is available with a stuffing-box cover designed for a packing and a BigBore or a

TaperBore PLUS seal chamber.

Optional seal