Maintenance

a) Install the seal-chamber cover or backplate (184) and fasten with nuts (370H).

b) Check the seal-chamber cover runout.

Rotate the indicator through 360 degrees. If the total indicator reading is greater than
0.005 in. (0.13 mm), determine the cause and correct the issue before you proceed.

Model 3196 i-FRAME Installation, Operation, and Maintenance Manual

119