Maintenance

• If No: Place a sling from the hoist through the frame adapter (108) or the frame (228A)

for the STi.

3. Remove the hold-down bolts of the bearing frame foot.
4. Remove the casing bolts.

WARNING:

• Never use heat to disassemble the pump due to the risk of an explosion from trapped liquid.

5. Tighten the jackscrews evenly, using an alternating pattern, in order to remove the back

pull-out assembly.
You can use penetrating oil if the adapter to the casing joint is corroded.

6. Remove the back pull-out assembly from the casing (100).
7. Mark and remove the shims from under the frame foot and save them for reassembly.
8. Remove and discard the casing gasket.

You will insert a new casing gasket during reassembly.

9. Remove the jackscrews.
10. Clean all gasket surfaces.

Clean surfaces prevent the casing gasket from partially adhering to the casing due to
binders and adhesives in the gasket material.