Installation

Permitted indicator values for alignment checks

NOTICE:The specified permitted reading values are valid only at operating temperature. For
cold settings, other values are permitted. You must use the correct tolerances. Failure to do so
can result in misalignment and reduced pump reliability.

When dial indicators are used to check the final alignment, the pump and drive unit are
correctly aligned when these conditions are true:

• The total indicator runout is a maximum of 0.002 in. (0.05 mm) at operating temperature.

• The tolerance of the indicator is 0.0005 in./in. (0.0127 mm/mm) of indicator separation at

operating temperature.

Cold settings for parallel vertical alignment

Introduction

This section shows the recommended preliminary (cold) settings for electric motor-driven
pumps based on different temperatures of pumped fluid. Consult driver manufacturers for
recommended cold settings for other types of drivers such as steam turbines and engines.

Recommended settings for models 3196, CV 3196, and LF 3196

Pumpage temperature

Recommended setting

50°F (10°C)

0.002 in. (0.05 mm), low

150°F (65°C)

0.001 in. (0.03 mm), high

250°F (120°C)

0.005 in. (0.12 mm), high

350°F (175°C)

0.009 in. (0.23 mm), high

450°F (218°C)

0.013 in. (0.33 mm), high

550°F (228°C)

0.017 in. (0.43 mm), high

650°F (343°C)

0.021 in. (0.53 mm), high

700°F (371°C)

0.023 in. (0.58 mm), high

Alignment measurement guidelines

Guideline

Explanation

Rotate the pump coupling half and the driver

This prevents incorrect measurement.

coupling half together so that the indicator rods
have contact with the same points on the
driver coupling half.
Move or shim only the driver in order to make

This prevents strain on the piping installations.

adjustments.
Make sure that the hold-down bolts for the

This keeps the driver stationary since move-

driver feet are tight when you take indicator

ment causes incorrect measurement.

measurements.
Make sure that the hold-down bolts for the

This makes it possible to move the driver when

driver feet are loose before you make align-

you make alignment corrections.

ment corrections.
Check the alignment again after any mechani- This corrects any misalignments that an ad-
cal adjustments.

justment may have caused.

Attach the dial indicators for alignment

You must have two dial indicators in order to complete this procedure.
1. Attach two dial indicators on the pump coupling half (X):

a) Attach one indicator (P) so that the indicator rod comes into contact with the perimeter

of the driver coupling half (Y).
This indicator is used to measure parallel misalignment.

Model 3196 i-FRAME Installation, Operation, and Maintenance Manual