Maintenance

This table shows which brand of grease to use when lubricating the pump.

Pumpage temperature less than Pumpage temperature greater
350°F (177°C)

than 350°F (177°C)

NGLI consistency

2

3

Mobil

Mobilux EP2

SCH32

Exxon

Unirex N2

Unirex N3

Sunoco

Mutipurpose 2EP

N/A

SKF

LGMT 2

LGMT 3

Convert from greased-for-life or regreaseable to oil-lubricated bearings

1. Remove the plug from the oil-return slot in the frame located under the radial bearing. Use

this table as a guide.

Pump model

Action

STi

Remove the epoxy from the return slot.

MTi, LTi, XLT-i, and i-17

Remove the set screw installed in the oil-return hole.

2. Remove the plug from the oil-return hole in the bearing housing (134).
3. Replace both bearings with unshielded, oil-lubricated bearings.

Table 24: Bearing types

Outboard bearing

Frame

Inboard bearing

Double row

Duplex

STi

6207

3306

7306

MTi

6309

3309

7309

LTi

6311

Not applicable

7310

XLT-i, i17

6313

3313

7313

4. Remove the grease fittings (193) to prevent accidental greasing.

Two plugs (408H) are required to replace the two grease fittings.

Item Number

Size

Description

Quantity

113

1/4"-18 NPT

External hex/square

2

head pipe plug

113A

1/2"-14 NPT

External hex/square

1

head pipe plug

193

1/4"-18 NPT

Grease fitting

2

228

- - - -

Bearing frame

1

241

- - - -

Frame foot

1

370F

1/2"

Hex cap screw

2