Position
Description
0
Controller
1
Fixing bracket for standard mounting
2
EMC shield sheet with fixing screws for shielded control cables
3
Cover with fixing screws
4
Shield clamp and strain relief for the motor cable
5
Strain relief for the PE motor cable and the feed cable for the motor temperature monitoring with PTC thermistor
or thermal contact (NC contact)
Connections and interfaces
Position
Description
L1, L2, L3, PE Mains connection
^ 153
+UG, −UG
DC supply
^ 153
U, V, W, PE
Motor connection
^ 153
T1, T2
Connection of PTC thermistor or thermal contact (NC contact) of the motor
^ 153
X1
AIF interface (automation interface)
Slot for communication module (e. g. XT EMZ9371BC keypad)
−
X3
Jumper for setting analog input signal at X6/1, X6/2
^ 199
X4
System bus (CAN) connection
^ 203
X5
Connection of digital inputs and outputs
^ 192
X6
Connection of analog inputs and outputs
^ 192
X7
Connection of resolver and KTY temperature sensor of the motor
^ 204
X8
Connection of incremental encoder with TTL level or SinCos encoder and KTY temperature sensor
of the motor
^ 204
X9
Connection of digital frequency input signal
^ 208
X10
Connection of digital frequency output signal
X11
Connection of K
SR
relay output for "safe standstill" (for variants V004 and V104 only)
^ 195
Status displays
Position
LED red
LED green
Operating status
Off
On
Controller enabled
On
On
Mains is switched on and automatic start is inhibited
Off
Blinking slowly
Controller inhibited
Blinking quickly
Off
Undervoltage or overvoltage
Blinking slowly
Off
Active fault
0Fig. 0Tab. 0