Operation at 480 v, Technical data, Rated data operation at 480 v – Lenze 9300 0.37kW-75kW User Manual
Page 131: 2 operation at 480 v
![background image](/manuals/566007/131/background.png)
Technical data
Rated data
Operation at 480 V
l
131
EDKVS9332X DE/EN/FR 6.1
9300
Output currents
8 kHz
1)
16 kHz
1)
Rated current
Maximum
current
2)
Standstill current
Rated current
Maximum
current
2)
Standstill current
Type
I
r8
[A]
I
M8
[A]
I
08
[A]
I
r16
[A]
I
M16
[A]
I
016
[A]
EVS9321−xx
1.5
2.25
2.3
1.1
1.65
1.7
EVS9322−xx
2.5
3.75
3.8
1.8
2.7
2.7
EVS9323−xx
3.9
5.85
5.9
2.9
4.35
4.4
EVS9324−xx
7.0
10.5
10.5
5.2
7.8
7.8
EVS9325−xx
13.0
19.5
19.5
9.7
14.6
14.6
EVS9326−xx
23.5
35.3
23.5
15.3
23.0
15.3
EVS9327−xx
32.0
48.0
32.0
20.8
31.2
20.8
EVS9328−xx
47.0
70.5
47.0
30.6
45.9
30.6
EVS9329−xx
59.0
88.5
52.0
38.0
57.0
33.0
EVS9330−xx
89.0
133.5
80.0
58.0
87.0
45.0
EVS9331−xx
110
165
110
70.0
105
70.0
EVS9332−xx
145
21.5
126
90.0
135
72.0
Bold print = Lenze setting
1)
Switching frequency of the inverter
2)
The currents apply to a periodic load change cycle with max. 1 minute overcurrent duration and 2 minutes base load
duration at max. 75 % I
r
3.3.2
Operation at 480 V
Basis of the data
Voltage
Frequency
Supply
3/PE 480 V AC
[U
r
]
320 V − 0 % ... 528 V + 0 %
45 Hz − 0 % ... 65 Hz + 0 %
DC 678 V (alternatively)
[U
DC
]
460 V − 0 % ... 740 V + 0 %
˘
Output voltage
With mains choke
3 ~ 0 ... approx. 94 % U
r
˘
Without mains choke
3 ~ 0 ... U
r
˘