Operation at 480 v, Technical data, Rated data operation at 480 v – Lenze 9300 0.37kW-75kW User Manual

Page 131: 2 operation at 480 v

Advertising
background image

Technical data

Rated data

Operation at 480 V

3

l

131

EDKVS9332X DE/EN/FR 6.1

9300

Output currents

8 kHz

1)

16 kHz

1)

Rated current

Maximum

current

2)

Standstill current

Rated current

Maximum

current

2)

Standstill current

Type

I

r8

[A]

I

M8

[A]

I

08

[A]

I

r16

[A]

I

M16

[A]

I

016

[A]

EVS9321−xx

1.5

2.25

2.3

1.1

1.65

1.7

EVS9322−xx

2.5

3.75

3.8

1.8

2.7

2.7

EVS9323−xx

3.9

5.85

5.9

2.9

4.35

4.4

EVS9324−xx

7.0

10.5

10.5

5.2

7.8

7.8

EVS9325−xx

13.0

19.5

19.5

9.7

14.6

14.6

EVS9326−xx

23.5

35.3

23.5

15.3

23.0

15.3

EVS9327−xx

32.0

48.0

32.0

20.8

31.2

20.8

EVS9328−xx

47.0

70.5

47.0

30.6

45.9

30.6

EVS9329−xx

59.0

88.5

52.0

38.0

57.0

33.0

EVS9330−xx

89.0

133.5

80.0

58.0

87.0

45.0

EVS9331−xx

110

165

110

70.0

105

70.0

EVS9332−xx

145

21.5

126

90.0

135

72.0

Bold print = Lenze setting

1)

Switching frequency of the inverter

2)

The currents apply to a periodic load change cycle with max. 1 minute overcurrent duration and 2 minutes base load
duration at max. 75 % I

r

3.3.2

Operation at 480 V

Basis of the data

Voltage

Frequency

Supply

3/PE 480 V AC

[U

r

]

320 V − 0 % ... 528 V + 0 %

45 Hz − 0 % ... 65 Hz + 0 %

DC 678 V (alternatively)

[U

DC

]

460 V − 0 % ... 740 V + 0 %

˘

Output voltage

With mains choke

3 ~ 0 ... approx. 94 % U

r

˘

Without mains choke

3 ~ 0 ... U

r

˘

Advertising