Technical data, General data and operating conditions, 3technical data – Lenze 9300 0.37kW-75kW User Manual

Page 127

Advertising
background image

Technical data

General data and operating conditions

3

l

127

EDKVS9332X DE/EN/FR 6.1

3

Technical data

3.1

General data and operating conditions

General data

Conformity and approval

Conformity

CE

2006/95/EC

Low−Voltage Directive

2004/108/EG

EMC Directive

Approbation

UL

UL 508C

Industrial Control Equipment
File No. E132659
for USA and Canada

Protection of persons and equipment

Type of protection

EN 60529

IP20

IP41 in case of thermally separated installation (push−through
technique) between the control cabinet (inside) and the
environment.

NEMA 250

Protection against accidental contact in accordance with type
1

Earth leakage current

IEC/EN 61800−5−1

> 3.5 mA

Observe regulations and safety
instructions!

Insulation of control
circuits

EN 61800−5−1

Safe mains isolation by double (reinforced) insulation for
terminals X1 and X5.
Basic insulation (single isolating distance) for terminals X3, X4,
X6, X7, X8, X9, X10 and X11.

Insulation resistance

IEC/EN 61800−5−1

< 2000 m site altitude: overvoltage category III

> 2000 m site altitude: overvoltage category II

Protective measures

Against short circuit, earth fault (earth−fault protected during
mains connection, limited earth−fault protection during
operation), overvoltage, motor overtemperature (input for PTC
or thermal contact)

EMC

Noise emission

IEC/EN 61800−3

Cable−guided, up to 10 m motor cable length with mains
filter A: category C2.

Radiation, with mains filter A and installation in control
cabinet: category C2

Interference immunity

IEC/EN 61800−3

Category C3