Mechanical installation

Standard devices in the power range 55 ... 75 kW
Thermally separated mounting (push−through technique)

4

l

152

EDKVS9332X DE/EN/FR 6.1

4.4.3

Thermally separated mounting (push−through technique)

For mounting in push−through technique, the drive controller of type EVS93xx−Exx must
be used. In addition, the mounting set EJ0009 for the push−through technique is required.

Dimensions

h

c1

c2

c3

c4

g

a1

a

d1

h

d2

d2

d2

d

b

b1

e1

e

L

9300std071

Fig. 4−14

Dimensions for thermally separated mounting 55 ... 75 kW

9300

Dimensions [mm]

Typ

a

a1

b

b1

c1

c2

c3

c4

d

d1

d2

e

1)

e1

g

h

EVS9331−Ex
EVS9332−Ex

488

450

718

680

49

172.5

295.5

419

698

49

200

285

164

9

10

1)

For a fieldbus module plugged onto X1, consider mounting space for connecting cables

Mounting cutout in control cabinet

9300

Dimensions [mm]

Type

a1

b1

EVS9331−Ex
EVS9332−Ex

428.5

660