Mechanical installation, Dimensions, Mounting cutout in control cabinet – Lenze 9300 0.37kW-75kW User Manual
Page 137
![background image](/manuals/566007/137/background.png)
Mechanical installation
Standard devices in the power range 0.37 ... 11 kW
Thermally separated mounting (push−through technique)
l
137
EDKVS9332X DE/EN/FR 6.1
4.1.3
Thermally separated mounting (push−through technique)
For mounting in push−through technique you have to use the controller type EVS93xx−Ex.
Additionally you will require the mounting set for push−through technique:
Type
Mounting set
EVS9321−Ex, EVS9322−Ex
EJ0036
EVS9323−Ex, EVS9324−Ex
EJ0037
EVS9325−Ex, EVS9326−Ex
EJ0038
Dimensions
a1
a1
c1
c1
a
a
c
c
g
g
d1
d1
d1
d1
d
d
b1
b1
b
b
L
L
1
0
e
f
9300std063
Fig. 4−2
Dimensions for thermally separated mounting 0.37 ... 11 kW
9300
Dimensions [mm]
Type
a
a1
b
b1
c
c1
d
d1
e
1)
f
g
EVS9321−Ex
EVS9322−Ex
0
112.5
78
385.5
350
60
95.5
365.5
105.5
250
92
6.5
EVS9323−Ex
EVS9324−Ex
0
131.5
97
385.5
350
79
114.5
365.5
105.5
250
92
6.5
EVS9325−Ex
EVS9326−Ex
1
169.5
135
385.5
350
117
152.5
365.5
105.5
250
92
6.5
1)
For a fieldbus module plugged onto X1, consider mounting space for connecting cables
Mounting cutout in control cabinet
9300
Dimensions [mm]
Type
Width
Height
EVS9321−Ex
EVS9322−Ex
0
82
350
EVS9323−Ex
EVS9324−Ex
0
101
350
EVS9325−Ex
EVS9326−Ex
1
139
350