Electrical installation

Standard devices in the power range 15 ... 30 kW

Important notes

5

l

167

EDKVS9332X DE/EN/FR 6.1

5.5

Standard devices in the power range 15 ... 30 kW

5.5.1

Important notes

To gain access to the power connections, remove the cover:

Remove the cover of the drive controller

0

1

1. Remove the screws

0

2. Lift cover

1 up and detach it

9300vec113

Installation material required from the scope of supply:

Description

Use

Quantity

Hexagon nut M6 (DIN 934)

Connection of supply cables (mains, +U

G

, −U

G

) and

motor cable to the stud bolts

10

Washer

Æ 6 mm (DIN 125)

For hexagon nut M6

10

Spring washer

Æ 6 mm (DIN 127)

For hexagon nut M6

10

Grommet

Motor cable

1

Shield connection support

Support of the shield sheet for motor cable

1

Self−tapping screw

Ж 4 Ч 14 mm

Fastening of shield connection support

2

Shield sheet

Shield connection for motor cable

1

5.5.2

Mains connection, DC supply

)

Note!

ƒ

If a mains filter or RFI filter is used and the cable length between mains/RFI
filter and drive controller exceeds 300 mm, install a shielded cable.

ƒ

For DC−bus operation or DC supply, we recommend using shielded DC
cables.