Electrical installation

Wiring of the feedback system
Important notes

5

l

204

EDKVS9332X DE/EN/FR 6.1

5.10

Wiring of the feedback system

5.10.1

Important notes

The feedback signal can either be supplied via input X7 or via input X8.

ƒ

At X7 a resolver can be connected.

ƒ

At X8 an encoder can be connected.
– Incremental encoder TTL
– SinCos encoder
– SinCos encoder with serial communication (single−turn or multi−turn)

The resolver or encoder signal for slave drives can be output at the digital frequency output
X10.

)

Note!

ƒ

We recommend to use Lenze system cables for wiring.

ƒ

For self−made cables only use cables with shielded cores twisted in pairs.

Installation material required from the scope of supply:

Description

Use

Quantity

Protective cover

Protection for unused Sub−D connections

4