Terminal assignment, Electrical installation, 5 terminal assignment analog input configuration – Lenze 9300 0.37kW-75kW User Manual
Page 199: Non−configurable control terminals
![background image](/manuals/566007/199/background.png)
Electrical installation
Wiring of the control connections
Terminal assignment
l
199
EDKVS9332X DE/EN/FR 6.1
5.8.5
Terminal assignment
Analog input configuration
Terminal
Jumper strip X3
Jumper setting
Possible levels
X6/1, X6/2
1
3
5
2
4
6
1−2
1)
−10 V ... +10 V
1)
3−4
−10 V ... +10 V
5−6
−20 mA ... +20 mA
1)
Lenze setting (delivery state)
Non−configurable control terminals
Terminal
Description
Function
Level / state
X11/K32
X11/K31
Safety relay K
SR
1st disconnecting
path
Pulse inhibit feedback
Open contact: pulse
inhibit is inactive
(operation)
Closed contact: pulse
inhibit is active
X11/33
– coil of safety relay K
SR
Coil is not carrying any
current: pulse inhibit is
active
X11/34
+ coil of safety relay K
SR
Coil is carrying current:
pulse inhibit is inactive
(operation)
X5/28
Controller inhibit
(DCTRL−CINH)
2nd disconnecting
path
Controller enable/inhibit
LOW: Controller
inhibited
HIGH: Controller enabled
X5/ST1
X5/ST2
STATE−BUS
Lenze setting of the configurable control connections for the 9300 Servo PLC
Terminal
Description
Function
Level
X5/E1
Digital inputs
Not assigned
HIGH
X5/E2
Not assigned
HIGH
X5/E3
Not assigned
HIGH
X5/E4
Not assigned
HIGH
X5/E5
Not assigned
HIGH
X5/A1
Digital outputs
Not assigned
HIGH
X5/A2
Not assigned
HIGH
X5/A3
Not assigned
HIGH
X5/A4
Not assigned
HIGH
X6/1, X6/2
Analog inputs
Not assigned
−10 V ... +10 V
X6/3, X6/4
Not assigned
−10 V ... +10 V
X6/62
Analog outputs
Not assigned
−10 V ... +10 V
X6/63
Not assigned
−10 V ... +10 V