Terminal assignment, Electrical installation, 5 terminal assignment analog input configuration – Lenze 9300 0.37kW-75kW User Manual

Page 199: Non−configurable control terminals

Advertising
background image

Electrical installation

Wiring of the control connections

Terminal assignment

5

l

199

EDKVS9332X DE/EN/FR 6.1

5.8.5

Terminal assignment

Analog input configuration

Terminal

Jumper strip X3

Jumper setting

Possible levels

X6/1, X6/2

1

3

5

2

4

6

1−2

1)

−10 V ... +10 V

1)

3−4

−10 V ... +10 V

5−6

−20 mA ... +20 mA

1)

Lenze setting (delivery state)

Non−configurable control terminals

Terminal

Description

Function

Level / state

X11/K32
X11/K31

Safety relay K

SR

1st disconnecting
path

Pulse inhibit feedback

Open contact: pulse
inhibit is inactive
(operation)

Closed contact: pulse
inhibit is active

X11/33

– coil of safety relay K

SR

Coil is not carrying any
current: pulse inhibit is
active

X11/34

+ coil of safety relay K

SR

Coil is carrying current:
pulse inhibit is inactive
(operation)

X5/28

Controller inhibit
(DCTRL−CINH)
2nd disconnecting
path

Controller enable/inhibit

LOW: Controller
inhibited
HIGH: Controller enabled

X5/ST1
X5/ST2

STATE−BUS

Lenze setting of the configurable control connections for the 9300 Servo PLC

Terminal

Description

Function

Level

X5/E1

Digital inputs

Not assigned

HIGH

X5/E2

Not assigned

HIGH

X5/E3

Not assigned

HIGH

X5/E4

Not assigned

HIGH

X5/E5

Not assigned

HIGH

X5/A1

Digital outputs

Not assigned

HIGH

X5/A2

Not assigned

HIGH

X5/A3

Not assigned

HIGH

X5/A4

Not assigned

HIGH

X6/1, X6/2

Analog inputs

Not assigned

−10 V ... +10 V

X6/3, X6/4

Not assigned

−10 V ... +10 V

X6/62

Analog outputs

Not assigned

−10 V ... +10 V

X6/63

Not assigned

−10 V ... +10 V